images

Working Hours

Mon - Sat 10:00 - 6:30

images

Call Us

08045800581

L And T MN5 9-15 A Overload Relay
L And T MN5 9-15 A Overload Relay
L And T MN5 9-15 A Overload Relay
L And T MN5 9-15 A Overload Relay
L And T MN5 9-15 A Overload Relay
L And T MN5 9-15 A Overload Relay

L And T MN5 9-15 A Overload Relay

Price 250 INR/ Piece

MOQ : 10 Pieces

L And T MN5 9-15 A Overload Relay Specification

  • Surface Finish
  • Matte
  • Efficiency
  • High
  • Feature
  • Manual reset
  • IP Rating
  • IP20
  • Overheating Protection
  • YES
  • Mounting Type
  • Direct/Separate
  • Connector Type
  • Screw terminal
  • Product Type
  • Overload Relay
  • Application
  • Motor Protection
  • Protection Level
  • Overload
  • Rated Voltage
  • 690V
  • Energy Consumption
  • Low
  • Color
  • Black & White
  • Dimension (L*W*H)
  • Approx. 45x80x72 mm
  • Phase
  • Three Phase
  • Input Voltage
  • 415V
  • Size
  • For 9-15A range
  • Material
  • Thermoplastic, Metal Parts
  • No Of Poles
  • 3-pole
  • Mechanical Life
  • 30 ops/hr
  • Ambient temperature
  • -5 to 55 Degree C
  • Built-in contacts
  • 2NO + 1NC
  • Trip Class
  • 10A
  • Rated Insulation Voltage Ui (V)
  • 690V
  • Model No
  • MN5 9-15 A
  • Rated operational current at 415V
  • 2A
  • Discount Percentage
  • 0-10%
  • Rated impulse withstand voltage (Uimp)
  • 6kV
  • Start/Off/Reset
  • 1 Start & 1 OFF/Reset
  • Conformance to Standards
  • IS/IEC 60947-4-1
 

L And T MN5 9-15 A Overload Relay Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About L And T MN5 9-15 A Overload Relay



Discover the supreme L And T MN5 9-15 A Overload Relay, designed to deliver top-drawer motor protection with premium efficiency and low energy consumption. This trending product features a robust three-phase build, 3-pole design, and offers perfect suitability for 9-15A ranges. Its manual reset and advanced overload, overheating protection ensure seamless operations. Engineered for durability with thermoplastic and metal parts, the relay meets IS/IEC standards. Order today at the best price-trusted by exporters, suppliers, and traders across India!

Key Features & Perfect Applications

The L And T MN5 9-15 A Overload Relay boasts high mechanical life and a secure IP20 rating, making it an ideal fit for industrial, commercial, and motor control environments. Used by manufacturers and engineers, this top-drawer relay is suitable for direct or separate mounting, providing reliable protection for motors against overloads and overheating. Its matte finish, built-in NO/NC contacts, and precise manual reset capability ensure versatility and supreme reliability for demanding operational needs.


Market Arrival & Flexible Supply Offerings

Experience the latest market value with the arrival of the L And T MN5 9-15 A Overload Relay. Available with a reliable FOB port, we offer sample options upon request to ensure your requirements are met before you commit. With a consistent supply ability, this product is trending amongst traders and exporters. Take advantage of our current offers and ensure your order is fulfilled with efficiency and precision to meet today's operational standards.


FAQ's of L And T MN5 9-15 A Overload Relay:


Q: How can I install the L And T MN5 9-15 A Overload Relay?

A: The L And T MN5 9-15 A Overload Relay can be installed directly or separately, depending on your application needs. Its screw terminal connector ensures straightforward mounting for both options.

Q: What benefits does the manual reset feature provide?

A: The manual reset allows users to easily restore operation after a trip event, adding safety and preventing accidental restarts, which is crucial for motor protection.

Q: Where can this overload relay be used?

A: This relay is suitable for use in industrial settings, motor control panels, and commercial applications requiring reliable three-phase motor protection.

Q: When should I consider ordering the L And T MN5 9-15 A Overload Relay?

A: Order today to ensure your operations benefit from trending, top-drawer motor protection with best price availability and consistent supply.

Q: What is the usage process for this overload relay?

A: Once installed, the relay monitors motor current. If overload or overheating is detected, it trips to protect the motor. Use the manual reset feature to resume normal operation after correcting the issue.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Schneider Electric Category

L And T MN2 24-40 A Overload Relay

L And T MN2 24-40 A Overload Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Product Type : Overload Relay

No Of Poles : 3

Phase : Three Phase

Application : Motor Protection

L And T MN5 66-110 A Overload Relay

L And T MN5 66-110 A Overload Relay

Minimum Order Quantity : 1 Piece

Product Type : Overload Relay

No Of Poles : 3

Phase : Three Phase

Application : Motor Protection

Lc1d 50 Contactor

Lc1d 50 Contactor

Price 1250 INR / Piece

Minimum Order Quantity : 1 Piece

Product Type : Lc1d 50 Contactor

No Of Poles : 3 Pole

Phase : Three Phase

Application : Industrial Control

LC1D25 3 Pole Schneider Contactor

LC1D25 3 Pole Schneider Contactor

Price 650 INR / Piece

Minimum Order Quantity : 1 Piece

Product Type : AC Power Contactors

No Of Poles : 3 Pole

Phase : 3

Application : Industrial



arrow